APC Power-Saving Back-UPS Pro 1200, 230V BR1200GI - C2000
[BR1200GI]

TEMPORARILY OUT OF STOCK


Part Number: BR1200GI

Manufacturer: APC

Condition: New

Short Description:

APC Power-Saving Back-UPS Pro 1200, 230V BR1200GI

APC Power-Saving Back-UPS Pro 1200, 230V BR1200GI - C2000

£220.00
£264.00 - Inc VAT




PLEASE TYPE IN THE PART NUMBER IN THE SEARCH BOX
Click the Like Button below to see the latest discount:

The Back-UPS RS offers high performance protection for your business and office computer systems. It provides abundant battery backup power, allowing you to work through medium and extended length power outages. It also safeguards your equipment from damaging surges and spikes that travel along utility, phone and network lines. A distinguishing feature of the Back-UPS RS is automatic voltage regulation (AVR). AVR instantly adjusts both low and high voltages to safe levels, so you can work indefinitely during brownouts and overvoltage situations, saving the battery for power outages when you need it most. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and plentiful outlets (including transformer-block spaced outlets) make the Back-UPS RS the perfect unit to protect your business' productivity from the constant threat of power problems and lost data.
Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Audible alarms: Provide notification of changing flywheel conditions
Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Power-saving outlets: Automatically cuts power to idle equipment to conserve electricity.
LCD display: Alpha-Numeric Display which displays system parameters and alarms.
Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
Cold-start capable: Provides temporary battery power when the utility power is out.
Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms: Provides notification of changing utility power and UPS conditions.
User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
USB connectivity: Provides management of the UPS via a USB port (not available on all models).
Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.
Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery
Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit.
Adjustable voltage sensitivity: Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.
Automatic Voltage Regulation (AVR): Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Battery fault detection: Monitors room and individual battery temperature changes for early detection of thermal runaway, shorted cells, open circuit, and bad battery.
Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment.
Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
Audible alarms: Provides notification of changing utility power and UPS conditions.
Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery replacement without tools: Allows quick, easy battery replacement.
LED status indicators: Quickly understand unit and power status with visual indicators.
Cold-start capable: Provides temporary battery power when the utility power is out.
Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Resettable circuit breakers: Enables a quick recovery from overload events.
Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.
User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Intelligent battery management: Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.

Reviews

Specs

Weight & dimensions
Width 112 mm
Depth 380 mm
Height 301 mm
Weight 11.6 kg
Package weight 13.2 kg
Package width 238 mm
Package depth 488 mm
Package height 387 mm
Operational conditions
Operating temperature (T-T) 0 - 40 °C
Storage temperature (T-T) -15 - 45 °C
Operating relative humidity (H-H) 0 - 95%
Storage relative humidity (H-H) 0 - 95%
Operating altitude 0 - 9000 m
Non-operating altitude 0 - 15000 m
Power
Output power capacity (VA) 1200 VA
Output power 720 W
Power supply input frequency 50/60
Surge energy rating 441 J
Output power capacity 1200 VA
Input operation voltage (min) 156 V
Input operation voltage (max) 300 V
Efficiency 98.8%
Crest factor 3:1
Output frequency regulation 50/60
Ports & interfaces
Modem (RJ-11) ports 1
USB 2.0 ports quantity 1
Ethernet LAN (RJ-45) ports 1
AC outlets quantity 10 AC outlet(s)
AC outlet types C13 coupler
USB port Y
Number of output IEC jumpers 2
Certificates
Certification A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV, REACH, \nPEP, EOLI
RoHS compliance Y
Energy Star certified Y
Other features
Interface USB
Output connections IEC 320 C13, IEC 320 C13, IEC Jumpers
Input connection type IEC-320 C14
Nominal output voltage 230
Package dimensions (WxDxH) 238 x 488 x 387 mm
Networking features 10/100/1000 Base-T
Nominal input voltage 230
Battery
Battery technology Sealed Lead Acid (VRLA)
Battery type APCRBC124
Battery recharge time 8 h
Replacement battery cartridge 1
Typical backup time at half load 15.7 min
Typical backup time at full load 5.4 min
Hot-swap battery Y
Cold start Y
Automatic battery test Y
Battery life (max) 5 year(s)
Battery capacity 187 VAh
Packaging content
Bundled software PowerChute Personal Edition
Cables included Phone (RJ-11), USB cable
Manual Y
Warranty card Y
Software CD Y
Packaging content Qty 2- Detachable IEC Power Cord
Design
Colour of product Black
Display LCD
Performance
Noise level 45 dB
Audible alarms Yes
UPS topology Line-Interactive
Hold time (min) 10 ms
Hold time (max) 12 ms
Surge protection Y
Surge protection features Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone
Waveform Sine
Automatic Voltage Regulation (AVR) Y
Audible alarm(s) Y
Audible alarm modes Low battery alarm, Overload alarm
Technical details
Input connections IEC-320 C14
Logistics data
Quantity per pallet 24 pc(s)
Quantity per master carton 1 pc(s)

Features

APC Back-UPS Pro. Output power capacity: 1200 VA, Output power: 720 W, Input operation voltage (min): 156 V. AC outlet types: C13 coupler, AC outlets quantity: 10 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Battery type: APCRBC124, Battery recharge time: 8 h. Colour of product: Black, Display: LCD. UPS topology: Line-Interactive, Hold time (min): 10 ms, Hold time (max): 12 ms

Product Description

The Back-UPS RS offers high performance protection for your business and office computer systems. It provides abundant battery backup power, allowing you to work through medium and extended length power outages. It also safeguards your equipment from damaging surges and spikes that travel along utility, phone and network lines. A distinguishing feature of the Back-UPS RS is automatic voltage regulation (AVR). AVR instantly adjusts both low and high voltages to safe levels, so you can work indefinitely during brownouts and overvoltage situations, saving the battery for power outages when you need it most. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and plentiful outlets (including transformer-block spaced outlets) make the Back-UPS RS the perfect unit to protect your business' productivity from the constant threat of power problems and lost data.
Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Audible alarms: Provide notification of changing flywheel conditions
Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Power-saving outlets: Automatically cuts power to idle equipment to conserve electricity.
LCD display: Alpha-Numeric Display which displays system parameters and alarms.
Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
Cold-start capable: Provides temporary battery power when the utility power is out.
Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Audible alarms: Provides notification of changing utility power and UPS conditions.
User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
USB connectivity: Provides management of the UPS via a USB port (not available on all models).
Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.
Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery
Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery.
Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.
Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit.
Adjustable voltage sensitivity: Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.
Automatic Voltage Regulation (AVR): Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
Battery fault detection: Monitors room and individual battery temperature changes for early detection of thermal runaway, shorted cells, open circuit, and bad battery.
Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment.
Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.
Audible alarms: Provides notification of changing utility power and UPS conditions.
Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery replacement without tools: Allows quick, easy battery replacement.
LED status indicators: Quickly understand unit and power status with visual indicators.
Cold-start capable: Provides temporary battery power when the utility power is out.
Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Resettable circuit breakers: Enables a quick recovery from overload events.
Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.
User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Intelligent battery management: Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.

Currently viewing: APC Power-Saving Back-UPS Pro 1200, 230V BR1200GI - C2000
Categories
Customer Testimonials

Excellent service and very quick delivery. Great communication. Would recommend.

(read more)
By Mark Harman

Mr
Wonderful company, printer delivered in 48 hours and looks to be in good shape. Proof will be in the ...

(read more)
By Leslie


We have been purchasing papers from Athema Services Ltd since 2008. | Items Price: Competitively Che ...

(read more)
By Di Gong

Mr
Very fast and effective communication throughout the sales order process, including helpful advice o ...

(read more)
By Simon Dean

Mr
Excellent, smooth and a quick process from start to finish, hoping my next day delivery will be deli ...

(read more)
By Andy Helm

Write a Testimonial
View All Testimonials
Mailing List:
Sign up for our latest offers and promos:
E-mail address: